Enhance security and improve availability in Industry 4.0 factories
2026-11-25
Safety is crucial when designing Industry 4.0 production lines. For example, subsystems such as motors and drives typically must meet the International Electrotechnical Commission (IEC) 62061 Safety Integrity Level (SIL) 2 and the International Organization for Standardization (ISO) 13849-1 Performance Level (PL) c. To meet these requirements, you can usually use contactors to safely connect and disconnect motors. For small motors with a power below 55 kW, standard contactors can provide a simple and cost-effective method.
As many of us have discovered, for motors with higher power levels, meeting IEC and ISO safety requirements becomes more complex and expensive due to the need for coupling devices between the motor and standard contactors. Fortunately, there are currently some enhanced contactors on the market with built-in fault safety functions that can be directly connected to motors with power ranging from 55 to 250 kW, thereby reducing system costs and component count, and enhancing reliability.
Next, we will take Siemens' innovative safety level contactor as an example to briefly introduce a simplified architecture suitable for motors with power ranging from 55 to 250 kW, which uses a fault safety contactor. At the end of this article, we will also discuss some of the related challenges encountered in quantifying the performance of safety grade contactors using Verband Deutscher Maschinen und Anlagenbau (VDMA) and German Machinery and Factory Building Association standards.
Using safety grade contactors to achieve simplification Contactors suitable for power levels up to approximately 55 kW can be directly connected to the output terminals of fault safety controllers and safety relays to meet safety level application requirements. The output of these fail safe controllers and safety relays is typically limited to 5 A or less current (24 VDC). Due to their lack of punch heads necessary for controlling high-power contactors, coupling devices are required between the controller/safety relay and standard contactors to enhance driver power. These coupling devices will increase costs and complexity, and occupy more space.
To address this issue, Siemens has developed an innovative approach that uses contactors that not only include standard driver coils but also fail safe control inputs. The fault safety control input can operate at a driving current of approximately 5 A at 24 VDC, while traditional contactors require 5 A or greater current at 24 VDC. This means that the contactor can be driven directly from the safety relay and fault safety controller.
Even if the fail safe contactor is controlled by the fail safe control input, the contactor coil can still be permanently connected to the supply voltage to ensure reliable operation (Figure 1).
Figure 1: The traditional contactor (left) requires coupling devices (two blue boxes in the upper right), but not when using the fault safety contactor (right). (Image source: Siemens)
Fault safe operation Siemens offers a range of innovative Sirius modular control options, including contactors that provide traditional AC/DC and integrated fault safety control modes of operation. The fault safety working mechanism can be selectively equipped with residual life (RLT) signals to indicate the wear condition of the contacts. This can achieve preventive maintenance, thereby further improving system reliability and availability. The RLT circuit can store contact wear information for all three main contacts. Contact wear is indicated by LED indicator lights; When the RLT of the most severely worn contact drops to 20%, additional relay output will be generated.
Due to their ability to connect to the output of the fail safe controller, these contactors are called F-PLC-IN contactors and can be identified by the yellow marked terminals or coil housings on the fail safe control input (Figure 2).
Figure 2: The F-PLC-IN contactor can be visually identified by yellow marked terminals or coil housings, such as 3RT2037-1SF30 (left) and 3RT1056-6SF36 (right). (Image source: Siemens)
Digital indicators of security VDMA standard data sheet 66413 specifies four types of devices that can be used for safety assessment:
The development purpose of Class 1 devices is to be used in safety functions, such as safety relays and fault safety programmable logic controllers (PLCs), and to meet specific SIL or PL requirements. The development purpose of Class 2 devices may not necessarily be to meet specific safety requirements and requires application data to evaluate safety operations. Three types of devices include easily worn components, such as electromechanical contactors. Their development purpose may not necessarily be to meet specific security requirements and may require extensive security assessments. The development purpose of Class 4 devices is to be used in safety functions without encountering random faults. The Sirius F-PLC-IN contactor has integrated electronic components and is not purely an electromechanical component, therefore it cannot be classified as a Class 3 device. They actually belong to Class 1 devices, meet specific SIL and PLC requirements, and comply with comprehensive safety related specifications. Compared to standard contactors, they can simplify safety integrity calculation tasks (Table 1).