How to implement protection, auxiliary power supply, and connection for electric vehicles (EVs) and their power supply equipment
2026-11-25
Electric vehicles (EVs) are playing an increasingly important role in reducing greenhouse gas (GHG) emissions to address climate change. However, to successfully design and deploy electric vehicles and electric vehicle power supply equipment (EVSE) such as battery chargers, designers must overcome various technical challenges. These challenges include overvoltage and overcurrent circuit protection, electromagnetic interference suppression (EMI), power supply design with wide input and operating temperature range, and the need to continuously reduce weight to improve the range of electric vehicles.
For example, the battery management system (BMS) and control interface in the EVSE system require an auxiliary AC/DC power supply, with an input voltage of 85 V to 305 VAC and a temperature range of -40 ° C to+85 ° C. To address weight issues, designers need to replace the mature CAN bus with automotive grade Ethernet, which can use lighter cables to support higher bandwidth.
This article will briefly introduce the basic polarization of electric vehicle chargers. Then discuss the different requirements of each charger related to the auxiliary AC/DC power supply (auxiliary power supply), provide overvoltage and overcurrent protection options, and introduce how to achieve Ethernet connection and suppress EMI to avoid high-speed signal distortion. Using solutions provided by suppliers such as Bel Fuse, Signal Transformer, Stewart Connector, and CUI as examples, illustrate how to solve various design problems.
Introduction to EV and EVSE Charging Requirements Deploying a large number of EVSEs (including battery chargers and charging stations) will be the key to the popularization of electric vehicles. Please note that the EV battery charger is located inside the electric vehicle, while the charging station refers to an external charging station. The North American EV connector standard SAE J1772 defines four EV charging levels:
AC Level 1 uses 120 VAC voltage and outputs up to 16 A or 1.9 kW; AC Level 2 uses 208 V to 240 V AC voltage and outputs up to 80 A or 19.2 kW DC Level 1 uses up to 1000 VDC voltage and outputs up to 80 A or 80 kW DC Level 2 uses up to 1000 VDC voltage and outputs up to 400 A or 400 kW Although SAE defines the above two DC levels separately, they are often mixed and referred to as Level 3 or DC fast charging. In addition to different input voltages and power levels, AC charging stations also require the installation of a separate on-board charger (OBC) in the vehicle to handle AC/DC conversion and BMS functions, in order to safely and efficiently charge the battery pack. In the case of DC fast charging, OBC is not required; The power conversion and BMS functions are both located in the charging station. Each level of charging includes communication (signal) between the vehicle and the charging station (Figure 1).
Three charging levels for electric vehicles Figure 1: Electric vehicle charging is usually divided into three levels. The third level (bottom) combines two DC charging levels specified in SAE J1772. (Image source: CUI)
Auxiliary power demand According to the requirements of SAE J1772, when connecting the charging station controller to the vehicle controller, it is necessary to use an auxiliary power supply to achieve general operation and signal functions of the charging station. The purpose of the signal protocol is to utilize the continuous bidirectional connection between the charging station and the vehicle to ensure the efficiency and safety of charging.
The basic power requirements are AC/DC power supply, which provides 12 VDC voltage for signal transmission and operates within a temperature range of -40 ° C to+85 ° C. A complete solution requires electromagnetic compatibility (EMC) and protection circuits, and typically requires a separate DC/DC converter to provide lower voltage for other components, such as 3.3 V voltage for powering microcontroller units (MCUs).
The specific power demand depends on the design of the charging station. For example, a Level 1 charger has a simple design and extremely low power requirements. The auxiliary power can be provided by a small 5 W AC/DC power supply installed on a printed circuit board (PC board). Level 2 charging stations are relatively complex and require approximately 50 W of auxiliary power. Both types of charging stations use single-phase AC input, but the input voltage requirements are different: level 1 is 120 VAC, and level 2 is 208 V to 240 VAC.
The third level charging station is very different from the first two levels. The internal charging circuit of the charging station uses a three-phase power supply, usually 480 VAC. The auxiliary power supply adopts single-phase power supply and requires a wide input voltage range, such as 85 V to 305 VAC. The output power is also relatively high, usually 150 W or more, which allows for more functions, including payment functions, display screens, BMS and other control functions. This level of charging station can provide a single output, such as providing 24 VDC output to power the entire system. The system will provide the required 12 VDC voltage for signals through a series of distributed DC/DC converters, providing separate 12 VDC voltage for BMS and 3.3 VDC voltage for MCU and other components. In addition to EMC and standard protection features, these power solutions also require power factor correction (PFC) and prevent high surge currents when turned on.
auxiliary power supply The good news for designers is that they don't have to build auxiliary power supplies from scratch. On the contrary, the CUI department under Bel Fuse now provides ready-made solutions for various types of EV charging stations. For example, PBO series 3 W, 5 W, 8 W, and 10 W onboard AC/DC power supplies are suitable for level 1 chargers. The PBO-5C-12 model has an input voltage of 85 V to 305 VAC, an output power of 5 W, a direct output voltage of 12 VDC, and a rated operating temperature range of -40 ° C to+85 ° C.
The secondary charging station requires more auxiliary power supply, and can use PSK series AC/DC power supply, such as enclosed 10 W PSK-10D-12. This power supply can provide 830 mA current at 12 VDC voltage. The input voltage range and operating temperature of this power supply are the same as PBO-5C-12. Both PBO and PSK series provide overcurrent and short-circuit protection functions, while PSK series adds overvoltage protection function.
For Level 3 charging stations, CUI's VGS series AC/DC power supply can provide up to 350 W of power. These power supplies have short-circuit, overcurrent, overvoltage, and overheat protection functions, as well as surge current limiting and active PFC functions. These power supplies comply with CISPR/EN55032 Class B radiation/conduction emission standards and IEC 61000-3-2 Class A harmonic limitation standards. VGS-100W-24 belongs to this type of power supply. The output power of this power supply is 108 W, the output voltage is 24 VDC, and the typical efficiency is 89.5% (Figure 2).